beautypg.com

Procedure for enabling infoserver network booting – HP BA322 90087 User Manual

Page 228

background image

Table C-1 InfoServer Booting: Differences Between Alpha and Integrity server Systems (continued)

Integrity servers

Alpha

Component

Only those BOOTP servers having the
network device MAC address defined in the
BOOTP database

Any MOP-enabled system with the specified
file

Boot server

InfoServer application running on OpenVMS
Alpha Version 8.3 or OpenVMS Integrity
servers Version 8.2-1 or later.

InfoServer hardware, or InfoServer utility
running on OpenVMS Alpha Version 8.3 or
later, or on OpenVMS Integrity servers Version
8.2-1 or later

LAN server

Because of these differences, any procedures used for Alpha systems to set up booting from the
InfoServer hardware are not valid for setting up booting from the OpenVMS InfoServer utility.
In addition, actions for setting up booting from the OpenVMS Integrity servers InfoServer utility
differ from those required for setting up booting from an OpenVMS Alpha InfoServer utility.

Table C-2

lists the various actions that need to be performed to enable network booting using

the OpenVMS InfoServer utility on OpenVMS Integrity servers or OpenVMS Alpha systems.
These actions need be performed only once except where noted.

Table C-2 Procedure for Enabling InfoServer Network Booting

InfoServer Client Setup

Section

Actions Required

Architecture

Section C.2 (page 229)

1. Determine the LAN I/O card to be used on your local Integrity

servers for the network boot and report the associated OpenVMS
device name, its IP address, and its MAC address to the network
administrator responsible for setting up the BOOTP server.

2. Optionally (and recommended), add this network device as an

EFI boot option—this procedure can be repeated on any other
system in the LAN that will use the InfoServer server for network
booting.

3. Verify that the network device is supported by EFI as a bootable

device.

Integrity servers
clients only

InfoServer Utility Setup

Section

Actions Required (You or Network Administrator)

Architecture

Upgrade instructions in

Chapter 6 (page 103)

.

Prior to upgrading,
review

Chapter 4

(page 83)

, and

Chapter 5 (page 95)

.

Designate at least one OpenVMS system in the LAN as the InfoServer
server. Upgrade the system if necessary (OpenVMS Integrity servers
must be Version 8.2-1 or later; OpenVMS Alpha must be Version
8.3 or later).

Integrity servers or
Alpha

Section C.3 (page 232)

.

1. Copy SYS$STARTUP:ESS$LAD_STARTUP.TEMPLATE to

SYS$STARTUP:ESS$LAD_STARTUP.DAT and then modify
parameters in SYS$STARTUP:ESS$LAD_STARTUP.DAT.

2. Determine which network device will be used for InfoServer LAD

operations.

3. Copy SYS$STARTUP:ESS$LAST_STARTUP.TEMPLATE to

SYS$STARTUP:ESS$LAST_STARTUP.DAT and then modify
parameters in SYS$STARTUP:ESS$LAST_STARTUP.DAT.

4. Add a line to SYS$MANAGER:SYSTARTUP_VMS.COM to start

the SYS$STARTUP:ESS$LAD_STARTUP.COM file at startup.

5. If you changed any SYSGEN parameters, run AUTOGEN and

reboot; if you did not change SYSGEN parameters, skip the reboot
and execute the SYS$STARTUP:ESS$LAD_STARTUP.COM file
manually.

6. Use the InfoServer control program to create a service for the

DVD drive.

Integrity servers or
Alpha

228

Setting Up and Performing Network Booting