38 external control of output on/off, External control of output on/off -23, S. 3.3.39 – KEPCO KLN Series (750W, 1500W, 3000W), Main Contro Firmware Version 1.70 and higher User Manual
Page 69: R. 3.3.39 to enable), R. 3.3.40 to enable), R. 3.3.39, R. 3.3.40

KLN Series 051614
3-23
3.3.38
EXTERNAL CONTROL OF OUTPUT ON/OFF
This function enables or disables external control of output on/off using the Programming Con-
trol port.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(EO.C) to access EXTERNAL OUTPUT ON/OFF CONTROL function.
OFF (default) displayed as
(OFF) in Current display.
ON displayed as
(ON) in Current display.
2. Press ENTER key to change setting. Rotate encoder until Current display shows desired
setting, then press ENTER to confirm.
3.3.39
ENABLE VOLTAGE CONTROL VIA PROGRAMMING CONTROL PORT
Allows voltage control either from the front panel (LOCAL) or from the analog signal via the Pro-
gramming Control port (EXTERNAL)
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(CV.M) to access CONSTANT VOLTAGE MODE CONTROL setting.
2. Press ENTER key to view setting.
LOCAL (front panel) mode displayed as
(LOC) in Current display.
EXTERNAL (Programming Control port) mode displayed as
(EXT) in Current
display.
3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.
3.3.40
ENABLE CURRENT CONTROL VIA PROGRAMMING CONTROL PORT
Allows current control either from the front panel (LOCAL) or from the analog signal via the Pro-
gramming Control port (EXTERNAL)
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(CC.M) to access CONSTANT CURRENT MODE CONTROL setting.
2. Press ENTER key to view setting.
LOCAL (front panel) mode displayed as
(LOC) in Current display.
EXTERNAL (Programming Control port) mode displayed as
(EXT) in Current
display.
3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.