KLN Series 051614

1-3

3000W 2U Full Rack Models

KLN 6-400

0 to 6

0 to 400

23

1000

2.8

42

6.2

85

0.08

0.02

0.5

1

KLN 8-360

0 to 8

0 to 360

23

1000

2.8

42

6.2

85

0.08

0.02

0.5

1

KLN 12.5-240

0 to 12.5

0 to 240

23

800

3.2

29

7.1

60

0.08

0.1

0.8

1

KLN 20-150

0 to 20

0 to 150

23

600

4

18.5

8

38

0.08

0.1

0.8

1

KLN 30-100

0 to 30

0 to 100

23

310

5

13

9.5

27

0.08

0.16

0.9

1.5

KLN 40-76

0 to 40

0 to 76

23

250

6

10.5

11

22

0.08

0.16

1

2

KLN 50-60

0 to 50

0 to 60

23

200

7

9

13

19

0.08

0.16

1.1

2

KLN 60-50

0 to 60

0 to 50

23

150

8

7.5

14

16

0.08

0.16

1.1

3

KLN 80-38

0 to 80

0 to 38

23

110

10

6.2

17

13.4

0.15

0.3

1.2

4

KLN 100-30

0 to 100

0 to 30

23

90

12

5.3

20

11.6

0.15

0.3

1.5

5

KLN 150-20

0 to 150

0 to 20

36

90

17

4.2

27.5

9.4

0.15

0.3

2

5

KLN 300-10

0 to 300

0 to 10

57

50

32

3.1

50

7.2

0.15

0.3

3.5

5

KLN 600-5

0 to 600

0 to 5

170

30

62

2.55

95

6.1

0.25

0.5

4

5

NOTES:
1. Actual output voltage should be

0.1% of rated voltage when output voltage is set to zero.

2. Actual output current should be

0.2% of the rated current when output current is set to zero (resistive load).

3. Measured when output is within 10%-100% of rated value; ripple bandwidth: 300kHz (rms), noise bandwidth: <20MHz (p-p).
4. For 6V model: measured when output voltage 2-6V and rated current; all other models measured when output 10-100% of rated voltage and rated

current.

5. Input voltage 100-240V a-c (190-240V a-c for 3000W models), 50/60Hz, constant load.
6. Constant input voltage and output from no load to full load.
7. With rated input, resistive load.
8. Rated power output with input 115V or 230V a-c
9. Specifications met after 30 minutes of operation, ambient temperature 23±5°C, humidity under 80% R. H, nominal a-c input voltage ±5%, THD

2%, not using the remote compensation, not operating in series or parallel.

10. For example, the spec for KLN 6-100 line regulation and load regulation in CV mode is 0.05% + 2.8mV (or 6 x 0.0005 = 3mV +2.8mV =5.8mV).
11. Add G suffix for models with optional GPIB interface, add E suffix for optional LAN interface.
12. Specifications subject to change without notice.

TABLE 1-2. KLN GENERAL SPECIFICATIONS

SPECIFICATION

RATING/DESCRIPTION

INPUT CHARACTERISTICS

Input voltage

750W, 1500W:

3000W:

100~240Vac, 50/60Hz
127V~373V d-c

(1)

190~240Vac, 50/60Hz
254V~370V d-c

(1)

Input current (Full load)

750W:

1500W:
3000W:

115Vac - 8.1A; 230V a-c - 4.1A
115Vac - 16.2A; 230V a-c - 8.1A
230V a-c - 15.6A

Inrush current

750W:

1500W:
3000W:

230Vac - 12.5A
230Vac - 25A
230Vac - 50A

Power Factor (PF)
Typical

750W,1500W:

3000W:

0.99 (at 115V a-c, rated output)
0.99 (at 230V a-c, rated output)

(1) Connect (+) to L and (–) to N. Safety agency approvals apply to a-c input operation only.

TABLE 1-1. KLN SERIES MODEL PARAMETERS (CONTINUED)

Model

(8)(9)(11)(12)

d-c Output Range

Ripple

(3)

Line Regulation

(5)(10)

Load Regulation

(10)

Response Time

(7)

Remote

Sense

Voltage

drop

(max.)

Constant

Voltage

(CV)

(1)

Constant

Current

(CC)

(2)

CV

CC

(4)

CV

CC

CV

(6)

CC

(6)

Full

Load

Up

Full

Load

Down

No

Load

Down

V d-c

A d-c

mV

rms

mA

rms

0.05%

+mV

0.1%

+mA

0.05%

+mV

0.1%

+mA

Sec

Sec

Sec

V