KEPCO KLN Series (750W, 1500W, 3000W), Main Contro Firmware Version 1.70 and higher User Manual
Page 14

1-4
KLN Series 051614
OUTPUT CHARACTERISTICS
Type of Stabilizer
Constant Voltage (CV)/Constant Current (CC),
automatic crossover
Adjustment Range
Voltage:
Current:
0 to 100% of rated voltage
0 to 100% of rated current
Protective functions
Programmable overvoltage (OVP),
Programmable overcurrent (OCP),
Overtemperature (OTP),
Fuse blown
Protection setting range
Overvoltage:
Overcurrent:
0% to 110% of rated voltage
0% to 110% of rated current
Remote Error Sense Compensation
5V max. (See Table 1-1.)
Parallel Operation
Up to 5 units maximum, automatic load sharing
Current sharing tolerance:
1% at rated current, 5% at 50% of rated current, 10% at
less than 10% of rated current
Series Operation
2 units maximum (total voltage must not exceed 600V)
Temperature Coefficient
Constant Voltage Mode,
Constant Current Mode:
100ppm/°C of rated output voltage or current, after 30 min-
ute warm-up
Time (Drift)
Constant Voltage Mode,
Constant Current Mode:
0.05% of rated output voltage or current over 8hrs interval
following 30 minutes warm-up. Constant line, load and tem-
perature.
Transient response time
Constant Voltage mode:
20V and under:
1.5ms;
30V~100V:
1ms
150V~600V:
2ms
Hold-up time
20ms
Efficiency
750W:
1500W:
3000W:
76% – 87%
77% – 88%
82% – 88%
Isolation Voltage
Input - Outputs:
Input - Ground:
Output - Ground (6V-150V)
Output - Ground (300V-600V)
2000V a-c: 1 minute
2000V a-c: 1 minute
350V d-c, leakage current: 100
A
1200V d-c, leakage current: 100
A
PROGRAMMING CHARACTERISTICS - LOCAL
Display resolution
Voltage and Current:
4 digits (setting and display)
Display setting accuracy
Voltage:
Current:
±0.1% ± 3C
(2)
at rated voltage
±0.5% ± 3C
(2)
at rated current
Display reading accuracy
Voltage:
Current:
±0.2% ± 3C
(2)
at rated voltage
±0.5% ± 3C
(2)
at rated current
(2) C = 1 count of the last displayed digit.
TABLE 1-2. KLN GENERAL SPECIFICATIONS (CONTINUED)
SPECIFICATION
RATING/DESCRIPTION