Table 3-2. factory defaults, Factory defaults -5 – KEPCO KLN Series (750W, 1500W, 3000W), Main Contro Firmware Version 1.70 and higher User Manual

Page 51

background image

KLN Series 051614

3-5

• If an error occurs, the red

(alarm) LED goes on. Refer to PAR. 3.3.50 to view the

error code.

5. When the unit is turned on for the first time, the factory default conditions upon power up

after a successful self test are as shown in Table 3-2.

TABLE 3-2. FACTORY DEFAULTS

Parameter

Factory Default

Output V

10% of rated voltage (0V for E- or G- suffix models)

Output C

10% of rated current (0A for E- or G- suffix models)

OVP

110% of rated Voltage

OCP

110% of rated Current

Output: On/off

OFF

Power On: LAST/OFF

OFF

RAMP UP time

0.1

RAMP down time

0

Undervoltage Limit

0

BEEP: On/Off

On

I/O Select

RS 485

RS 485 Baud rate

115200

GPIB address

07

RS 485 address

007

Parallel/Series: PM/PS/SM/SS

PM

External Control of output: ON/OFF

OFF

Voltage Control: LOC/EXT

LOC

Current Control: LOC/EXT

LOC

Front panel lockout

OFF

Voltage Set: Direct/Enter

Direct

DHCP: On/Off

On

SYST:COMM:LAN:GATE

DHCP On: from DHCP server
DHCP Off: 0.0.0.0

SYST:COMM:LAN:IP

DHCP On: From DHCP server
DHCP Off: 192.168.0.100

SYST:COMM:LAN:IPAD

192.168.0.100

SYST:COMM:LAN:SMAS

255.255.255.0

SYST:COMM:LAN:MAC

70-46-42-XX-XX-XX

SYST:COMM:LAN:TEL:PORT 5025

NOTES:
(1) Parameters changed via front panel are saved when unit is powered off, and will be restored upon power-up.

Parameters changed via SCPI command are not saved when unit is turned off and are restored to the last
value entered from front panel when power is cycled on.

(2) *RST resets the following: Output to OFF, Output V to 0V, Output A to 0A, OVP to 110% of rated voltage, OCP

to 110% of rated current, Undervoltage Limit to 0, and front panel lockout to OFF. All other parameters shown
above are restored to the last value entered from front panel.

(3) Cycling power resets the following: Output to setting determined by Power On setting (see PAR. 3.3.9), Under-

voltage Limit to 0 and front panel lockout to OFF. All other parameters shown above are restored to the last
value entered from front panel.

(4) RST1 resets the IP address to 192.168.0.100/255.255.0.0 and clears the Gateway and DNS settings.
(5) Parameters for options are defined only when applicable (see Table 3-3).