Rs. 3.3.26 th – KEPCO KLN Series (750W, 1500W, 3000W), Main Contro Firmware Version 1.70 and higher User Manual
Page 65

KLN Series 051614
3-19
3.3.26
SET/VIEW 2ND PART OF SUBNET MASK ADDRESS (LAN INTERFACE ONLY)
Used to set (DHCP function is OFF) or view (DHCP is ON) part 2 (nnn) of the 4-part Subnet
Mask address (xxx.nnn.xxx.xxx) where nnn is a number from 0 to 255.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(S.MN2) if DHCP is OFF or
(V.MN2) if DHCP is ON.
2. Press ENTER key to view setting.
For example,
(255) displayed in Current display for subnet mask address
xxx.255.xxx.xxx.
3. If Voltage display shows
(S.MN2), set by rotating encoder until Current display
shows desired setting (tap encoder to adjust 10’s or 100’s digit more rapidly). Press ENTER
to confirm.
3.3.27
SET/VIEW 3RD PART OF SUBNET MASK ADDRESS (LAN INTERFACE ONLY)
Used to set (DHCP function is OFF) or view (DHCP is ON) part 3 (nnn) of the 4-part Subnet
Mask address (xxx.xxx.nnn.xxx) where nnn is a number from 0 to 255.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(S.MN3) if DHCP is OFF or
(V.MN3) if DHCP is ON.
2. Press ENTER key to view setting.
For example,
(255) displayed in Current display for subnet mask address
xxx.xxx.255.xxx.
3. If Voltage display shows
(S.MN3), set by rotating encoder until Current display
shows desired setting (tap encoder to adjust 10’s or 100’s digit more rapidly). Press ENTER
to confirm.
3.3.28
SET/VIEW 4TH PART OF SUBNET MASK ADDRESS (LAN INTERFACE ONLY)
Used to set (DHCP function is OFF) or view (DHCP is ON) part 4 (nnn) of the 4-part Subnet
Mask address (xxx.xxx.xxx.nnn) where nnn is a number from 0 to 255. The default subnet mask
address is 255.255.255.0.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(S.MN4) if DHCP is OFF or
(V.MN4) if DHCP is ON.
2. Press ENTER key to view setting.
For example,
(0) displayed in Current display for subnet mask address
xxx.xxx.xxx.0.
3. If Voltage display shows
(S.MN4), set by rotating encoder until Current display
shows desired setting (tap encoder to adjust 10’s or 100’s digit more rapidly). Press ENTER
to confirm.