37 parallel/serial master/slave setup, Parallel/serial master/slave setup -22, H 3.3.36 – KEPCO KLN Series (750W, 1500W, 3000W), Main Contro Firmware Version 1.70 and higher User Manual
Page 68

3-22
KLN Series 051614
3.3.35
SET/VIEW 3RD PART OF DNS ADDRESS (LAN INTERFACE ONLY)
Used to set (DNS function is OFF) or view (DNS is ON) part 3 (nnn) of the 4-part DNS address
(xxx.xxx.nnn.xxx) where nnn is a number from 1 to 254.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(S.DN3) if DNS is OFF or
(V.DN3) if DNS is ON.
2. Press ENTER key to view setting.
For example,
(8) displayed in Current display for DNS address xxx.xxx.8.xxx.
3. If Voltage display shows
(S.DN3), set by rotating encoder until Current display
shows desired setting (tap encoder to adjust 10’s or 100’s digit more rapidly). Press ENTER
to confirm.
3.3.36
SET/VIEW 4TH PART OF DNS ADDRESS (LAN INTERFACE ONLY)
Used to set (DNS function is OFF) or view (DNS is ON) part 4 (nnn) of the 4-part DNS address
(xxx.xxx.xxx.nnn) where nnn is a number from 1 to 254.
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(S.DN4) if DNS is OFF or
(V.DN4) if DNS is ON.
2. Press ENTER key to view setting.
For example,
(100) displayed in Current display for DNS address
xxx.xxx.xxx.100.
3. If Voltage display shows
(S.DN4), set by rotating encoder until Current display
shows desired setting (tap encoder to adjust 10’s or 100’s digit more rapidly). Press ENTER
to confirm.
3.3.37
PARALLEL/SERIAL MASTER/SLAVE SETUP
Used to establish unit as Master or Slave for parallel (maximum of five units including Master) or
series operation (maximum of two units including Master).
1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display
shows
(PSOP) to access Parallel/Serial Master/Slave Setting.
2. Press ENTER key to change setting.
Parallel Master displayed as
(PM) in Current display.
Parallel Slave displayed as
(PS) in Current display.
Serial Master displayed as
(SM) in Current display.
Serial Slave displayed as
(SS) in Current display.
3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.