B.56

SYSTem:COMMunicate:LAN:SMAS?

QUERY

SYST:COMM:LAN:SMAS?

Syntax:

Short Form: SYST:COMM:LAN:SMAS?Long Form: SYSTem:COMMunicate:LAN:SMAS?

Description:

Indicates Subnet Mask address assigned for communication via the LAN interface.

Return Format:

is text in the format xxx.xxx.xxx.xxx

Example:

SYST:COMM:LAN:IP? returns 255.255.0.0 to indicate the Subnet Mask address is set to
255.255.0.0.

B.57

SYSTem:COMMunicate:LAN:TELnet:PORT COMMAND

SYST:COMM:LAN:TEL:PORT

Syntax:

Short Form: SYST:COMM:LAN:TEL:PORT
Long Form: SYSTem:COMMunicate:LAN:TELnet:PORT

Description:

Assigns port to be used for Telnet communication via the LAN interface. KLN units use port
5025 for Telnet sessions. Changing this address requires that power to the KLN be cycled off, then
on.

Argument:

in text format, a number from 0 to 65535

Example:

SYST:COMM:LAN:TEL:PORT 5025 assigns port 5025 to be used during Telnet sessions. A Telnet
session can typically be started from a host computer shell by sending the IP address followed by
the port number, e.g., telnet 192.168.0.100 5025.

B.58

SYSTem:COMMunicate:LAN:TELnet:PORT?

QUERY

SYST:COMM:LAN:TEL:PORT?

Syntax:

Short Form: SYST:COMM:LAN:TEL:PORT?
Long Form: SYSTem:COMMunicate:LAN:TELnet:PORT?

Description:

Indicates port assigned for Telnet communication via the LAN interface.

Return Format: in text format, a number from 0 to 65535

Example:

SYST:COMM:LAN:TEL:PORT? returns 5025 to indicate port 5025 is assigned to be used during
Telnet sessions.

B.59

SYSTem:ERRor?

QUERY

SYST:ERR?

Syntax:

Short Form: SYST:ERR?

Long Form: SYSTem:ERRor?

Description:

Returns error codes and messages.

Return Format: is text format in -XXX XXXXXXXXXXXXX

Example:

Input command S0URce:VOLTage 2w will cause error. SYSTem:ERR? returns error code “-138,”
and sending SYSTem:ERR? again returns no error code “+0,”. Refer to Table for a complete list of
error codes.

TABLE B-2. ERROR CODES

Error Code

Explanation

0,“No error”

No error

72, “OVP”

Overvoltage protection error:
a. The output voltage exceeds the OVP value.
b. The Analog Programming input for output voltage setting is too high (higher than
OVP value).

73, “OCP”

Output current exceeds 110% of rated current, this OCP value is restricted by hardware
and not adjustable.

74, “REMOTE SENSE OVER”

The max. compensation voltage is 5V d-c (the sum of two wires, i.e. 2.5V d-c for each).

75, ““D2D Module 1 fault”

DC to DC converter module number 1 failed (only one module in 750W models).

76, ““D2D Module 2 fault”

DC to DC converter module number 2 failed (two modules in 1500W models).

77, “Analog shut-off shutdown”

a. The slave unit(s) failed when operating in parallel/series.
b. Pins 23 and Pin 24 of Analog Programming Port are shorted to shut-off the output.