B.27 source:memory:current:x? query, B.28 source:memory:list:x? query, B.29 source:memory:recall:x command – KEPCO KLN Series (750W, 1500W, 3000W), Main Contro Firmware Version 1.70 and higher User Manual
Page 100: B.30 source:memory:voltage:x command, B.31 source:memory:voltage:x? query, B.32 source:voltage command, B.27, Sour, B.28, B.29

B-6
KLN Series 051614
B.27
SOURce:MEMory:CURRent:X?
QUERY
SOUR:MEM:CURR:X?
Syntax:
Short Form: SOUR:MEM:CURR:X? Long Form: SOURce:MEMory:CURRent:X?
Description:
Returns current value stored in memory location X (in amperes).
Return Format:
Example:
SOURce:MEMory:CURRent:5? returns 1.16000E+01 (Current stored in memory location 3 is
11.6A).
B.28
SOURce:MEMory:LIST:X?
QUERY
SOUR:MEM:LIST:X?
Syntax:
Short Form: SOUR:MEM:LIST:X?
Long Form: SOURce:MEMory:LIST:X?
Description:
For the memory location defined by X, returns voltage (volts) and current (amperes) in sci-
entific notation.
Return Format:
Example:
SOURce:MEMory:LIST:3? returns 5.00000E+02, 2.50000E-00 (Voltage/Current stored in memory
location 3 is 50V, 2.5A).
B.29
SOURce:MEMory:RECall:X COMMAND
SOUR:MEM:REC:X
Syntax:
Short Form: SOUR:MEM:REC:X
Long Form: SOURce:MEMory:RECall:X
Description:
Restores power supply settings to the voltage and current values stored in memory loca-
tion defined by X. If the output is off, the recalled voltage and current set values are shown on the
front panel Voltage and Current displays. If the output is on, the output changes to the recalled
voltage and current values which are also shown on the front panel Voltage and Current displays.
Argument:
X is a number from 0 to 15 representing one of 16 memory locations
Example:
SOURce:MEMory:RECall:3 sets power supply setpoints to 50V and 2.5A (values previously stored
via either front panel or SOURce:MEMory:VOLTage:X and SOURce:MEMory:CURRent:X com-
mands). If output is on, output is changed to 50V, 2.5A. If output is off, set values of 50V and 2.5A
are displayed on the front panel.
B.30
SOURce:MEMory:VOLTage:X COMMAND
SOUR:MEM:VOLT:X
Syntax:
Short Form: SOUR:MEM:VOLT:X
Description:
Sets the memory location defined by X to the voltage value
Argument:
Example:
SOURce:MEMory:VOLTage:5 62.4 sets memory location 5 to 62.4V.
B.31
SOURce:MEMory:VOLTage:X?
QUERY
SOUR:MEM:VOLT:X?
Syntax:
Short Form: SOUR:MEM:VOLT:X? Long
Form:
SOURce:MEMory:VOLTage:X?
Description:
Returns voltage value stored in memory location X (in volts).
Return Format:
Example:
SOURce:MEMory:VOLTage:5? returns 6.24000E+01 (Voltage stored in memory location 5 is
62.4V).
B.32
SOURce:VOLTage COMMAND
SOUR:VOLT
Syntax:
Short Form: SOUR:VOLT
Long Form: SOURce:VOLTage
Description:
Sets the output voltage value. Maximum output voltage is 105% of rated voltage; minimum volt-
age is zero.
Argument:
are defined by model (e.g., for KLN 6-100, rated voltage is 6V, rated current is 100A).
Example:
SOURce:VOLTage 30 sets output voltage value to 30V.