3 specifications, Table 1-1. kln series model parameters (continued), Specifications -2 – KEPCO KLN Series (750W, 1500W, 3000W), Main Contro Firmware Version 1.70 and higher User Manual
Page 12: Kln series model parameters -2

1-2
KLN Series 051614
1.3
SPECIFICATIONS
Table 1-1 below indicates parameters that vary for different KLN models; Table 1-2 lists general
specifications that apply to all KLN models.
TABLE 1-1. KLN SERIES MODEL PARAMETERS
Model
(8)(9)(11)(12)
d-c Output Range
Ripple
(3)
Line Regulation
(5)(10)
Load Regulation
(10)
Response Time
(7)
Remote
Sense
Voltage
drop
(max.)
Constant
Voltage
(CV)
(1)
Constant
Current
(CC)
(2)
CV
CC
(4)
CV
CC
CV
(6)
CC
(6)
Full
Load
Up
Full
Load
Down
No
Load
Down
V d-c
A d-c
mV
rms
mA
rms
0.05%
+mV
0.1%
+mA
0.05%
+mV
0.1%
+mA
Sec
Sec
Sec
V
750W 1U Half Rack Models
KLN 6-100
0 to 6
0 to 100
10
180
2.8
11
2.8
23
0.08
0.05
0.6
1
KLN 8-90
0 to 8
0 to 90
10
180
2.8
11
2.8
23
0.08
0.05
0.6
1
KLN 12.5-60
0 to 12.5
0 to 60
10
120
4
8.5
4
18
0.08
0.05
0.8
1
KLN 20-38
0 to 20
0 to 38
10
76
4
5.8
4
12.6
0.08
0.05
0.8
1
KLN 30-25
0 to 30
0 to 25
10
63
5
4.5
5
10
0.08
0.08
0.9
1.5
KLN 40-19
0 to 40
0 to 19
10
48
6
3.9
6
8.8
0.08
0.08
1
2
KLN 50-15
0 to 50
0 to 15
10
43
8
3.6
8
8.2
0.08
0.08
1.1
2
KLN 60-12.5
0 to 60
0 to 12.5
10
38
8
3.25
8
7.5
0.08
0.08
1.1
3
KLN 80-9.5
0 to 80
0 to 9.5
10
29
10
2.95
10
6.9
0.15
0.15
1.2
4
KLN 100-7.5
0 to 100
0 to 7.5
10
23
12
2.75
12
6.5
0.15
0.15
1.5
5
KLN 150-5
0 to 150
0 to 5
16
18
17
2.5
17
6
0.15
0.15
2
5
KLN 300-2.5
0 to 300
0 to 2.5
25
13
32
2.25
32
5.5
0.15
0.15
3
5
KLN 600-1.25
0 to 600
0 to 1.25
75
8
62
2.13
62
5.26
0.25
0.3
4
5
1500W 1U Full Rack Models
KLN 6-200
0 to 6
0 to 200
15
360
2.8
18.5
2.8
38
0.08
0.05
0.6
1
KLN 8-180
0 to 8
0 to 180
15
360
2.8
18.5
2.8
38
0.08
0.05
0.6
1
KLN 12.5-120
0 to 12.5
0 to 120
15
248
3.4
14.5
4
28
0.08
0.05
0.8
1
KLN 20-76
0 to 20
0 to 76
15
152
4
9.6
4
20.2
0.08
0.05
0.8
1
KLN 30-50
0 to 30
0 to 50
15
125
5
7
5
15
0.08
0.08
0.9
1.5
KLN 40-38
0 to 40
0 to 38
15
95
6
5.8
6
12.6
0.08
0.08
1
2
KLN 50-30
0 to 50
0 to 30
15
85
7
5.2
7
11.4
0.08
0.08
1.1
2
KLN 60-25
0 to 60
0 to 25
15
75
8
4.5
8
10
0.08
0.08
1.1
3
KLN 80-19
0 to 80
0 to 19
15
57
10
3.9
10
8.8
0.15
0.15
1.2
4
KLN 100-15
0 to 100
0 to 15
15
45
12
3.5
12
8
0.15
0.15
1.5
5
KLN 150-10
0 to 150
0 to 10
24
45
12
3.5
12
8
0.15
0.15
2
5
KLN 300-5
0 to 300
0 to 5
38
25
32
2.5
32
6
0.15
0.15
3
5
KLN 600-2.5
0 to 600
0 to 2.5
113
15
62
2.26
62
5.5
0.25
0.3
4
5
NOTES:
1. Actual output voltage should be
0.1% of rated voltage when output voltage is set to zero.
2. Actual output current should be
0.2% of the rated current when output current is set to zero (resistive load).
3. Measured when output is within 10%-100% of rated value; ripple bandwidth: 300kHz (rms), noise bandwidth: <20MHz (p-p).
4. For 6V model: measured when output voltage 2-6V and rated current; all other models measured when output 10-100% of rated voltage and rated
current.
5. Input voltage 100-240V a-c (190-240V a-c for 3000W models), 50/60Hz, constant load.
6. Constant input voltage and output from no load to full load.
7. With rated input, resistive load.
8. Rated power output with input 115V or 230V a-c
9. Specifications met after 30 minutes of operation, ambient temperature 23±5°C, humidity under 80% R. H, nominal a-c input voltage ±5%, THD
2%, not using the remote compensation, not operating in series or parallel.
10. For example, the spec for KLN 6-100 line regulation and load regulation in CV mode is 0.05% + 2.8mV (or 6 x 0.0005 = 3mV +2.8mV =5.8mV).
11. Add G suffix for models with optional GPIB interface, add E suffix for optional LAN interface.
12. Specifications subject to change without notice.