5 215IF Module

5.5.4 Setting CP-215 Transmission Definitions

5-22

10.No. of Relayed Network 1

When the Message Relay Function is enabled (set to 1: Enable), this setting specifies the
range of network numbers (0 to 254) that can be relay destinations. Messages will not be
relayed to networks that are outside of the specified range. The network number in the
No. of Relayed Network 1 setting is ORed with the network number in the No. of
Relayed Network 2 setting. The Relay Function will be disabled if both settings are “0.”

For details, refer to 5.6 Relay Function.

11.No. of Relayed Network 2

See the explanation for the No. of Relayed Network 1 setting, above.

12.Maintenance Switch

These settings are all OFF during operation. These software switches are used for
Yaskawa maintenance. Do not change the settings.

„

Reverting to Defaults

The transmission parameters can be reset to their default values without inputting each
parameter, by selecting Edit (E) and then Default (S) from the menu in the CP-215 Trans-
mission Definitions Window.

Table 5.3 Default Values of Transmission Parameters

Parameter

Default

Own Station No

0

Own Network No

0

Token Cycle Time Setting

100

MEMOBUS Response Monitoring
Time

0

Station Search Interval

0

Transmission Speed

4

Max No. of Stations Connected

16

Message Relay Function

0

No. of Relayed Network 1

0

No. of Relayed Network 2

0

Maintenance Switches SW1

SW2

All OFF