8 Example Communications Module Applications

8.3.4 MELSEC Settings (AJ71UC24 Example)

8-20

„

Switch Settings

Station Number Setting Switches

Set 01 to 31, but not 0. (Recommended value: 01)

Communications Specification Setting Switches (For AJ71UC24 Mod-
ules)

Note: The shaded parts show setting examples.
* 1. The following table shows the settings of switches 13, 14 and 15.

* 2. With the AJ71C24-S8, the terminating resistance ON/OFF setting on

the transmission side depends on the wiring.

* 3. With the AJ71C24-S8, the terminating resistance ON/OFF setting on

the reception side depends on the wiring.

Switch Name

Setting

Set Value

(Recommended Value)

× 10 (rotary switches 0 to 9)

The second digit for station
number

0

× 1 (rotary switches 0 to 9)

The first digit for station
number

1

Switch Name

Setting Item

Setting Contents

Set

Value

ON

OFF

SW11

Main channel setting

RS-422

RS-232C

OFF

SW12

Data bit setting

8 bits

7 bits

ON

SW13

Transmission Speed set-
ting

See the following table.

*1

OFF

SW14

ON

SW15

ON

SW16

Parity bit setting

Yes

No

ON

SW17

Even parity
Odd parity

Even

Odd

ON

SW18

Stop bit setting

2 bits

1 bit

OFF

SW21

Checksum setting

Yes

No

ON

SW22

Write enable/disable set-
ting during RUN

Enabled

Disabled

ON

SW23

Computer link
Multi-drop

Computer link

Multi-drop link

ON

*2

SW24

Not used.

-

-

OFF

*3

bps

300

600

1,200

2,400

4,800

9,600

19,200

SW13

OFF

ON

OFF

ON

OFF

ON

OFF

SW14

OFF

OFF

ON

ON

OFF

OFF

ON

SW15

OFF

OFF

OFF

OFF

ON

ON

ON