Connector signal assignments, Cn2: operating status i/o connector (d-sub 9-pin) – Yaskawa MP920 Communications Module User Manual
Page 108

5.7 CP-215 Repeaters
5-47
5
Connector Signal Assignments
* Short-circuiting the RT1 and RT2 terminals connects the internal 75
Ω
terminating resistance.
CN2: Operating Status I/O Connector (D-sub 9-pin)
Note: For external connectors, use the D-sub 9-pin male connector: 17JE-
23090-02 (D8B) manufactured by Daiichi Electronic Industries Co.,
Ltd. This connector is equipped with a case and M3 mounting screws.
No.
Signal Name
No.
Signal Name
1
SRD-
5
RT2
*
2
Not used.
6
Not used.
3
Not used
7
Not used
4
RT1
*
8
SRD+
Name
Specifications
DO
RUN output (open collector output)
Allowable output capacity: 24 VDC, 50 mA or less
Turned OFF when the power is shut OFF or the reception carrier sense time
is exceeded for approximately one second or more.
Automatically restored when operation becomes normal.
DI
Dual switching input (24 VDC, 10 mA)
External power supply
Load
24 VDC
±20%
CN2-5
CN2-3
CN2-9
CN2-1
CN2-6
R
10mA
R
External power supply
24VDC
±20%
Operate when ON
Remain on hold when OFF
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)