3 Communications Protocols

3.2.3 MELSEC-A Protocol

3-8

Fig. 3.3 MELSEC Format Message Flow

Between a Controller and MELSEC-A

„

MELSEC Commands Supported by the 217IF

The following table shows the common MELSEC ACPU commands supported by the
MP900-Series 217IF Module, and the MEMOBUS command codes corresponding to these
commands.

Note: Special AnACPU commands are not supported. Use the common

ACPU commands for AnACPU access. AnACPU expansion registers
cannot be accessed.

CPU

MP900-Series Controller

MELSEC format

Ethernet

MSG-SND

217IF/

218IF

MELSEC-A

MSG-RCV

A2UCPU

AJ71E71

AJ71UC24

Table 3.3 Common MELSEC ACPU Commands

MEMOBUS

Command

MELSEC

Command

Description

Qty

Remarks

01H/02H

WR

Reads bit devices in 16-point units

32 words (512 points)

03H/04H

Reads word devices in 1-point units

64 points

0FH

WW

Writes bit devices in 16-point units

10 words (160 points)

10H

Writes word devices in 1-point units

64 points

08H

TT

Loopback test

254 characters