beautypg.com

3 module specifications, 1 hardware specifications, 2 communications specifications – Yaskawa MP920 Communications Module User Manual

Page 123

background image

6.3 Module Specifications

6-7

6

6.3

Module Specifications

This section explains the 217IF Module specifications.

6.3.1

Hardware Specifications

6.3.2

Communications Specifications

The following table shows the communications specifications for the 217IF Module.

* The maximum baud rate of the RS-422/485 (CN3) depends on the CN1

and CN2 baud rates. If 19.2 kbps is set for CN1 and CN2, then the maxi-
mum transmission speed for CN3 will be 19.2 kbps.

Item

Specifications

Name

217IF Communications Module (Serial Communications
Module)

Model

JEPMC-CM200

Description

217IF

Dimensions

40

× 130 × 105 mm (W × H × D)

(Size for one option slot of MP920)

Approximate Mass

Base: 200 g, Case: 165 g

Power Supply

Supplied from Base Module
+5 V, 300 mA

Table 6.3 217IF Module Communications Specifications

Item

Specifications

Interface

RS-232C: Two lines
RS-422/485: One line

Connector

RS-232C (CN1): D-sub 9-pin (female)
RS-232C (CN2): D-sub 9-pin (female)
RS-422/485 (CN3): MR-8 (female)

Transmission Distance

RS-232C: 15 m max.
RS-422/485: 300 m max.

Transmission Speed

RS-232C (CN1/CN2): 300 bps to 19.2 kbps
RS-422/485 (CN3): 2400 bps to 76.8 kbps

*

(300/600/1200/2400/4800/9600/14400/19200/28800/38400/
48000/ 57600/64000/76800 bps)

Access Method

Non-synchronous (start-stop synchronization)

Communications Mode

Message communications, engineering communications

Communications Protocol

MEMOBUS (Master/Slave), MELSEC Communications,
OMRON Communications

Connection Configuration

RS-232C: 1:1
RS-422: 1:1
RS-485: 1:N

Transmission Format
(Can be Set)

Data bit length: 7 or 8 bits
Stop bits: 1 or 2 bits
Parity bit: Even/Odd/None