D.5 Transmission Line Components
D-33
D
215IF Repeater-TS5 Transmission Line Components
* 1. Multi-mode Crystal Optical Fiber Cords and Cables for Long Wave-
length (1,300 nm)
* 1. L is 100 m, 200 m, 500 m, or 1,000 m.
* 2. L is 0.3 m, 1 m, 3 m, or 5 m. For 10 m or longer, specify the cable
length in 5-m units.
* 3. L is 1 m, 3 m, or 5 m. For 10 m or longer, specify the cable length in 5-
m units.
* 4. A pulling eyelet can be mounted to protect optical connectors. To spec-
ify this option, append “-P” at the end of the model number.
Note: 1. If optical connectors or optical fiber cables are to be connected on-
site, specify a cable length that allows some play at both ends.
2. When ordering cords or cables with non-standard specifications,
refer to D.6.4 Specifying Detailed Order Patterns.
3. For ordering, contact your Yaskawa representative.
4. Be sure that excessive tensile force or lateral pressure will not be
applied to the cord.
5. For outdoor installation, specify LAP sheaths.
6. Cable sheath is made of PVC. If there is a risk of the cable being
exposed to oil or chemicals that may damage PVC, it is recom-
mended using cable sheaths made of polyethylene (PE).
No.
Model (Manufactured by
Sumitomo Electric Industries,
Ltd.)
Usage
Specification
No. in D.6.2
of this
Appendix
External Specifications, etc.
1
CVS-EG-5/0702, L
*1
In-panel single-core cord
(1)
No sheath, cord only
2
CVS-EG-5/0702 with FC con-
nectors at one end, L
*2
In-panel single-core cord with FC
connector at one end
(1)
No sheath
3
CVS-EG-5/0702 with FC con-
nectors at both ends, L
*2
In-panel single-core cord with FC
connectors at both ends
(1)
No sheath
4
2GI-C-V-NM, (EG-5/0702), L
*1
Indoor two-core cable (for racks
and troughs)
(2)
Vinyl sheath, cable only
5
2GI-GS-E-NM, (EG-5/0702),
L
*1
Outdoor two-core cable (for racks,
troughs, and electrical conduits)
(3)
Polyethylene sheath, cable
only
6
2GI-L-4C-LAP, (EG-5/0702)
*1
Outdoor two-core cable (for racks,
troughs, and electrical conduits)
(4)
LAP sheath, cable only
7
2GI-C-LAP, (EG-5/0702), L
*1
Outdoor two-core cable (for racks,
troughs, and electrical conduits)
(5)
LAP sheath, cable only
8
2GI-C-V-NM with FC connec-
tors at both ends, (EG-5/0702),
L
*3 *4
Indoor two-core cable with FC con-
nectors at both ends (for racks and
troughs)
(5)
LAP sheath
9
2GI-C-LAP, (EG-5/0702) with
FC connectors at both ends,
L
*3*4
Outdoor two-core cable with FC
connectors at both ends (for racks,
troughs, and electrical conduits)
(5)
LAP sheath
10
2GI-L-4C-LAP-MAZE, (EG-5/
0702), L
*1
Two-core cable for vertical use
-
Equipped with steel pipe
11
2GI-L-4C-LAP-(with steel
pipe), (EGñ5/0702), L
Two-core cable for underwater use
-
Equipped with steel pipe