Legend-mc user’s manual – Yaskawa LEGEND-MC User Manual
Page 256

246
LEGEND-MC User’s Manual
Command
Definition
units
min
max
default
_IA
Returns the IP address as a 32 bit signed
number
address
0
2147483647
0
_IA1
Returns the Ethernet retry time
mSec
0
2147483647
250
_IA2
Returns the number of available handles
handles
0
6
6
_IA3
Returns the number of the handle using this
operand
handle
0
5
n/a
_IHh0
Returns the IP address as a 32 bit signed
number ("h" is handle "A" - "P")
address
-2147483648
2147483647
-1
_IHh1
Returns the slave port number
number
0
65535
0
_IHh2
Returns the handle status (See IH command
description)
status
-2
2
0
_IHh3
Returns ARP status
status
0 = Successful
1 = Failed
n/a
_II
Returns the bitmask of all inputs that are
selected as interrupts
configuration
0
127
0
_ILx
Integrator limit of the axis
voltage
-9.9988
9.9988
9.9988
_IPX
Current encoder position of axis
counts
-2147483648
2147483647
n/a
_ITx
S curve smoothing function value
constant
0.004
1
1
_JGx
Jog speed for that axis
counts/sec
0
8000000
25000
_KDx
Derivative Constant for PID loop
constant
0
4095.875
64
_KIx
Integrator for PID loop
constant
0
2047.875
0
_KPx
Proportional Constant for PID loop
constant
0
1023.875
6
_LC
Status of Lock Controller command
configuration
0 = UNLOCKED 2 = ALL LOCKED
0-Jan
_LE
Length of the vector
counts
0
2147483647
0
_LFx
Forward Limit Switch
status
0 = ACTIVE
1 = INACTIVE
n/a
_LM
Number of free locations in linear mode
buffer
n/a
0
511
n/a
_LRx
Reverse Limit Switch
status
0 = ACTIVE
1 = INACTIVE
n/a
_LS
The total number of program lines
lines
0
999
0
_LTx
Stop distance set in the Latch Target
Command
counts
-2147483648
2147483647
0
_LZ
Serial port leading zero removal
status
0 = OFF
1 = ON
0
_MW
Returns the current configuration of the
Modbus Wait Command
configuration
0 = OFF
1 = ON
1
_MOx
Current state of motor, enabled or not
status
0=ENABLED
1=DISABLED
0 / 1
_MTx
Type of motor
configuration
-1
1
1
_NBx
Returns the Notch Filter Bandwidth
Hertz
0
62
0.5
_NFx
Returns the Notch Frequency
Hertz
0
255
0
_NZx
Returns the Notch Zero
Hertz
0
62
0
_OCx
Returns the state of the Output Compare
Function
status
0
1
n/a
_ODx
Returns the state of the Output Compare
Function Auxiliary Encoder
status
0
1
n/a
_OEx
Indicates if servo enable signal will shut off if
"_Erx" is exceeded
status
0=NO
1=YES
0=NO
_OFx
Axis command offset
voltage
-9.9988
9.9988
0
_OPx
Entire byte or word of output port (x = output
bank 0-3)
byte or word
0
65535
0
P1CD
Status code of serial port
status
-1
3
n/a
P1CH
The last character received from serial port
character
0
255
n/a
P1NM
The last number received from serial port
number
-2147483648
2147483647
n/a
P1ST
The last string received from serial port
string
6 chars max
n/a
_PAx
Last commanded absolute position if
moving, otherwise current position
counts
-2147483648
2147483647
0