beautypg.com

Ra (record array), General – Yaskawa LEGEND-MC User Manual

Page 203

background image

193

LEGEND-MC User’s Manual

RA (Record Array)

[General]

DESCRIPTION:

The RA command selects up to four arrays for automatic data capture. The selected arrays must have been
dimensioned by the DM command. The data to be captured is specified by the RD command and time
interval by the RC command.

ARGUMENTS: RA n [ ],m [ ],o [ ],p [ ]

where

n,m,o,p are dimensioned arrays as defined by DM command. The [ ] contain nothing.

USAGE:

RELATED COMMANDS:

EXAMPLES:

NOTE: The record array mode is useful for recording the real-time motor position during motion. The data is automatically
captured in the background and does not interrupt the program sequencer. The record mode can also be used for a teach or
learn of a motion path.

While Moving

Yes

Default Value

---

In a Program

Yes

Default Format

---

Command Line

Yes

Can be Interrogated

No

Used as an Operand

No

Distributed Control

No, Local

"DM"

Dimension Array

"RD" Record

Data

"RC" Record

Interval

#Record

Label

DM POS[100]

Define array

RA POS[]

Specify Record Mode

RD _TP

Specify data type for record

RC 1

Begin recording at 2 msec intervals

PR 1000;BG

Start motion

EN

End