Gr (gear ratio), Motion, N is a signed number – Yaskawa LEGEND-MC User Manual
Page 129: 0 disables gearing
119
LEGEND-MC User’s Manual
GR (Gear Ratio)
[Motion]
DESCRIPTION:
GR specifies the Gear Ratio for the slave axis in electronic gearing mode. The master axis for the
LEGEND-MC is specified with the GA command. Gear ratio may range between +/-127.9999. The slave
axis will be geared to the actual position of the master. The master can go in both directions. GR 0 disables
gearing. If a limit switch is hit during gearing, then gearing is automatically disabled.
ARGUMENTS: GR n
where
n is a signed number.
0 disables gearing
USAGE:
OPERAND USAGE:
_GRn contains the value of the gear ratio where n is an axis letter.
EXAMPLES:
While Moving
Yes
Minimum Value
-127.9999
In a Program
Yes
Maximum Value
127.9999
Command Line
Yes
Default Value
0
Can be Interrogated
Yes
Default Format
3.4
Used as an Operand
Yes
Distributed Control
Specific Axis
#GEAR
GADX
GR .25
Specify gear ratio
GRY=2.5
Specify that the Y axis will gear to the
auxiliary encoder at a rate of 2.5 (assuming a
distributed control system is configured)
EN
End program
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)