119

LEGEND-MC User’s Manual

GR (Gear Ratio)

[Motion]

DESCRIPTION:

GR specifies the Gear Ratio for the slave axis in electronic gearing mode. The master axis for the
LEGEND-MC is specified with the GA command. Gear ratio may range between +/-127.9999. The slave
axis will be geared to the actual position of the master. The master can go in both directions. GR 0 disables
gearing. If a limit switch is hit during gearing, then gearing is automatically disabled.

ARGUMENTS: GR n

where

n is a signed number.

0 disables gearing

USAGE:

OPERAND USAGE:

_GRn contains the value of the gear ratio where n is an axis letter.

EXAMPLES:

While Moving

Yes

Minimum Value

-127.9999

In a Program

Yes

Maximum Value

127.9999

Command Line

Yes

Default Value

0

Can be Interrogated

Yes

Default Format

3.4

Used as an Operand

Yes

Distributed Control

Specific Axis

#GEAR

GADX

GR .25

Specify gear ratio

GRY=2.5

Specify that the Y axis will gear to the
auxiliary encoder at a rate of 2.5 (assuming a
distributed control system is configured)

EN

End program