Em (ecam cycle), Setting, N is the net change in the slave axis – Yaskawa LEGEND-MC User Manual
Page 114
104
LEGEND-MC User’s Manual
EM (ECAM Cycle)
[Setting]
DESCRIPTION:
The EM command is part of the ECAM mode. It is used to define the change in position over one complete
cycle of the slave. If a slave will return to its original position at the end of the cycle, the change is zero. If
the change is negative, specify the absolute value.
ARGUMENTS: EM n
where
n is the net change in the slave axis.
USAGE:
OPERAND USAGE:
_EMn contains the cam cycle of the slave where n is an axis letter.
RELATED COMMANDS:
EXAMPLES:
While Moving
Yes
Minimum n parameter
-2147483648
In a Program
Yes
Maximum n parameter
2147483647
Command Line
Yes
Default Value
0
Can be Interrogated
No
Default Format
---
Used as an Operand
Yes
Distributed Control
Use SA
"EB" Enable
Ecam
"EP"
CAM table intervals & starting point
"ET" Electronic
CAM
table
“MM”
Master Modulus
EM 2000
Define the net change in the slave to be 2000.
V = _EM
Return slave’s cam cycle distance
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)