beautypg.com

Emergency stop chain – Yaskawa LEGEND-MC User Manual

Page 23

background image

13

LEGEND-MC User’s Manual

Emergency Stop Chain

25

E STOP2

Legend-MC I/O

Connector CN5

50

VCC

-EROUT

1k

Q1

2N7002

U17

E STOP1

Internal Circuitry

Field Wiring

The LEGEND-MC closes the relay contact under normal operating conditions.

Ratings:

1.0A @ 24 VDC
0.5A @ 125 VAC

Maximum switching power: 62.5VA, 30W