PN (Legend Parameter)
[Configuration]
DESCRIPTION:
The PN command sets or returns data residing in the Legend amplifier. The PN command causes the
controller to communicate to the amplifier via a serial connection on the mating connector. The available
parameter numbers are listed below. If the parameter was not accepted by the amplifier, a command error
will result. (TC=131 Amplifier Error) Paraemters that are successfully sent to the amplifier are stored in
EEPROM memory and effective immediately. This memory is separate from the controller memory, so
performing a master reset on the controller will not reset these values.
ARGUMENTS: PN p,v where
p is the parameter number, typically entered as a hex value, this is amplifier standard.
v is the value of the parameter, in the units required by the parameter.
USAGE:
OPERAND USAGE:
_PNp will return the value of the parameter where p is the parameter number.
RELATED COMMANDS:
ADDITIONAL INFORMATION
:
EXAMPLES:
While Moving
Yes
Default Value
n/a
In a Program
Yes
Default Format
hex
Command Line
Yes
Can be Interrogated
Yes
Used as an Operand
Yes
Distributed Control
Use SA
"TS" Tell
Switches
Parameter
Description
Default
Min
Max
$400
Maximum Torque Reference Gain
Input (mV)
10000
1000
10000
$401
Torque Reference Filter Frequency
(0.01 ms)
10
0
65535
$402
Forward Torque Limit (%)
800
0
800
$403
Negative Torque Limit (%)
800
0
800
$407
Speed Limit under torque control
(0.1%)
1000
0
1000
PN $400,2000
Set torque reference gain
MG _PN$407
Read Speed Limit