beautypg.com

Lt (latch target), Motion, 40 stopped at latch target – Yaskawa LEGEND-MC User Manual

Page 167

background image

157

LEGEND-MC User’s Manual

LT (Latch Target)

[Motion]

DESCRIPTION:

The LT command is used for stopping an axis a defined distance after a registration mark (latch) input.
The distance specified by the LT command is in encoder counts. The distance must be sufficiently large
for the controller to decelerate normally at the specified deceleration rate. A stop code will be generated
if the distance is too small to stop for the deceleration rate or if the speed is too high. To Disable the latch
target, set LTX=0.

ARGUMENTS: LTX=x LTx,y,z,w LTa,b,c,d,e,f,g,h

POSSIBLE STOP CODES:

1 Motors stopped at commanded independent position (Latch input not received)

40 Stopped at Latch Target.

41 Latch Target overrun due to limit switch or stop command.

42 Latch Target overrun due to insufficient distance.

USAGE:

RELATED COMMANDS:

EXAMPLES:

While Moving

Yes

Default Value

n/a

In a Program

Yes

Default Format

---

Command Line

Yes

Can be Interrogated

Yes

Used as an Operand

Yes

Distributed Control

Specific Axis

"AL" Arm

Latch

"RL" Report

Latch

ALX

Set latch function

LTX=25000

Set Latch Target to stop 25000 counts
after registration

PRX=100000

Position Relative Move

BGX

Begin Motion

AMX

After Motion

JP #NOMRK,_SCX=1

Jump to #NOMARK routine if did not

receive a registration mark