The DC circuit breaker switches the Sunny Island 3324/4248 on and off. Note that
all voltage sources (batteries, (stand-alone) grid, generator) must be disconnected
from the Sunny Island 3324/4248 before the inverter is free of voltage (see section
9.3 "Switching Off" (Page 85)).
7.2
Changing Parameters
Use the
to navigate through the selected menu (see "Menu structure" figure Page 62) in order
to view or change parameter values. As soon as the desired parameter appears in
the display, you can read the current parameter value.
The display always shows the first two digits of a
parameter. The menu structure and the
parameter assignment are explained in section
7.5 "Menu Structure" (Page 61).
An "Enter" arrow is displayed next to parameters
that you are allowed to change
.
Note that some parameters can only be changed
when the inverter is in standby mode (see section
9.3 "Switching Off" (Page 85)). You can find the
parameters for which this applies in the tables in section 17.2.2 "Adjustable System
Parameters" (Page 134) and section17.2.4 "Operation (Operation)" (Page 141).
If you press the
use the arrow keys (↑ or ↓) to change the current parameter value.
As soon as the desired value appears in the display, press the
the new value, or press the
If you wish to exit the current menu level (e.g. "23-3 AmpHoursBat" parameter) then
press the
Settings" menu level.
AmpdcBatMax ‹23
10 A
↵
Screen display of (e.g.)
the
"23-4 AmpdcBatMax"
parameter: