Replacing the eprom – SMA SI 3324 Installation User Manual
Page 128

Updating Firmware
SMA
Technologie AG
Page 128
SI3324/4248-14:SE2406
Installation Guide
Replacing the EPROM
Follow the steps in the order below:
1.
Stop the Sunny Island 3324/4248 and switch it off as described in section 9.3
"Switching Off" (Page 85) and section 9.3 "Switching Off" (Page 85).
2.
Open the housing of the Sunny Island 3324/4248 (see section 6.1 "Removing
the Cover" (Page 55)).
3.
The EPROM is located in the lower right area of the inverter, in the smaller group
of raised components. This exact position can be seen in the following figure:
4.
Briefly touch the bare metal of the Sunny Island 3324/4248 housing (for
electrostatic discharge).
5.
Use the PLCC tool to remove the old EPROM, by carefully inserting the hooked
end of the tool into the right-hand cutout in the socket, thus allowing you to lever
the EPROM out of the socket at this corner. Carefully slide the tool under the
EPROM until you can remove the component from the socket.
6.
Remove the new EPROM provided from the protective packaging.
Take note of all parameter settings you have made before replacing the
EPROM.
12
3
Si-EL
V
1
.84
12
3
4
Si-EL
V1
.8
4
Sloping corner of the
EPROM oriented to the
bottom left
Socket cutout
(insert the tool
here)