SMA SI 3324 Installation User Manual
Page 34

Electrical Connection
SMA
Technologie AG
Page 34
SI3324/4248-14:SE2406
Installation Guide
Installation of the grounding conductors occurs in five steps:
1.
Install an M25 metric-thread cable screw connection (included in delivery) in the
"Grounding" cable feed-through (see figure Page 31).
-
Remove the dummy plug covering the cable feed-through.
-
Insert the metric-thread cable screw connection into the opening in the
housing.
-
Screw the counter-nut onto the cable screw connection thread inside the
housing.
2.
Remove the protective insulation from the conductor and fit a suitable cable end
sleeve to the exposed end of the conductor.
3.
Feed the grounding conductor through the metric-thread cable screw connection
into the housing of the Sunny Island 3324/4248.
4.
Insert the conductor with the cable end sleeve into the ground connection
terminal and tighten the screw firmly (torque 4.0 Nm to 5.7 Nm).
5.
Then tighten the metric-thread cable screw connection.
Steps
1. + 3., 5.
Step 4.