beautypg.com

Test run and program run 14.5 program run – HEIDENHAIN TNC 320 (34055x-06) User Manual

Page 456

background image

Test run and program run

14.5 Program run

14

456

TNC 320 | User's Manual HEIDENHAIN Conversational Programming | 5/2013

When a program run is interrupted, the TNC stores:

The data of the last defined tool

Active coordinate transformations (e.g. datum shift, rotation,
mirroring)

The coordinates of the circle center that was last defined

Note that the stored data remain active until they are
reset (e.g. if you select a new program).

The stored data are used for returning the tool to the contour after
manual machine axis positioning during an interruption (RESTORE
POSITION soft key).

Resuming program run with the START button

You can resume program run by pressing the machine START
button if the program was interrupted in one of the following ways:

Machine STOP button pressed

Programmed interruption

Resuming program run after an error

If the error message is not blinking:

Remove the cause of the error

Clear the error message from the screen: Press the CE key

Restart the program, or resume program run where it was
interrupted

If the error message is blinking

Press and hold the END key for two seconds. This induces a
TNC system restart

Remove the cause of the error

Restart

If you cannot correct the error, write down the error message and
contact your service agency