beautypg.com

Additional functions 8.8 – HEIDENHAIN TNC 320 (34055x-06) User Manual

Page 255

background image

Additional functions

8.8

8

TNC 320 | User's Manual HEIDENHAIN Conversational Programming | 5/2013

255

Keyword

Function

HOUR

Number of hours from the real-time clock

MIN

Number of minutes from the real-time
clock

SEC

Number of seconds from the real-time
clock

DAY

Day from the real-time clock

MONTH

Month as a number from the real-time
clock

STR_MONTH

Month as a string abbreviation from the
real-time clock

YEAR2

Two-digit year from the real-time clock

YEAR4

Four-digit year from the real-time clock

In the part program, program FN 16: F-PRINT to activate the
output:

96 FN 16: F-PRINT TNC:\MASKE\MASKE1.A/ TNC:\PROT1.TXT

The TNC then creates the file PROT1.TXT:
MEASURING LOG OF IMPELLER CENTER OF GRAVITY
DATE: 27:11:2001
TIME: 8:56:34
NO. OF MEASURED VALUES : = 1
X1 = 149.360
Y1 = 25.509
Z1 = 37.000

If you output the same file more than once in the
program, the TNC appends all texts to the end of the
texts already output within the target file.

If you use

FN 16 more than once in the program, the

TNC saves all texts in the file that you defined in the
FN 16 function. The file is not output until the TNC
reads the

END PGM block, or you press the NC stop

button, or you close the file with

M_CLOSE.

In the

FN 16 block, program the format file and the

log file with their respective extensions.

If you enter only the file name for the path of the
log file, the TNC saves the log file in the directory
in which the NC program with the

FN 16 function is

located.

You can define a standard path for outputting
protocol files via the user parameters
fn16DefaultPath and fn16DefaultPathSim (Program
Test).