Miscellaneous functions for path behavior

9.4

9

TNC 320 | User's Manual HEIDENHAIN Conversational Programming | 5/2013

317

Restrictions

After an external or internal stop, you can only re-enter the
contour with the function RESTORE POS. AT N. Before you start
the block scan, you must cancel M120, otherwise the TNC will
output an error message.

When using the path functions

RND and CHF, the blocks before

and after

RND or CHF must contain only coordinates in the

working plane.

If you want to approach the contour on a tangential path, you
must use the function APPR LCT. The block with APPR LCT
must contain only coordinates of the working plane

If you want to depart the contour on a tangential path, use the
function DEP LCT. The block with DEP LCT must contain only
coordinates of the working plane

Before using the functions listed below, you have to cancel
M120 and the radius compensation:

Cycle

32 Tolerance

Cycle

19 Working plane

PLANE function

M114

M128

TCPM FUNCTION