Datum Setting with 3-D Touch Probe

12.8

12

TNC 320 | User's Manual HEIDENHAIN Conversational Programming | 5/2013

423

Using touch probe functions with mechanical probes
or measuring dials

If you do not have an electronic 3-D touch probe on your machine,
you can also use all the previously described manual touch probe
functions (exception: calibration function) with mechanical probes
or by simply touching the workpiece with the tool.

In place of the electronic signal generated automatically by a
3-D touch probe during probing, you can manually initiate the
trigger signal for capturing the

probing position

by pressing a key.

Proceed as follows:

Select any touch probe function by soft key

Move the mechanical probe to the first position to
be captured by the TNC

Confirm the position: Press the actual-position-
capture soft key for the TNC to save the current
position

Move the mechanical probe to the next position to
be captured by the TNC

Confirm the position: Press the actual-position-
capture soft key for the TNC to save the current
position

If required, move to additional positions and
capture as described previously

Datum: In the menu window, enter the
coordinates of the new datum, confirm with the
SET DATUM soft key, or write the values to a table
(See "Writing measured values from the touch
probe cycles in a datum table", page 404, or
See
"Writing measured values from the touch probe
cycles in the preset table", page 405
)

Terminate the probing function: Press the END key