beautypg.com

Identifying basic rotation, Saving a basic rotation in the preset table – HEIDENHAIN TNC 320 (34055x-06) User Manual

Page 412

background image

Manual operation and setup

12.7 Compensating workpiece misalignment with 3-D touch probe

12

412

TNC 320 | User's Manual HEIDENHAIN Conversational Programming | 5/2013

Identifying basic rotation

Select the probe function by pressing the
PROBING ROT soft key

Position the touch probe at a position near the first
touch point

Select the probe direction perpendicular to the
angle reference axis: Select the axis by soft key

Start the probing procedure: Press the machine
START button

Position the touch probe at a position near the
second touch point

To probe the workpiece, press the machine START
button. The TNC determines the basic rotation and
displays the angle after the dialog

Rotation angle

Activate basic rotation: Press the SET BASIC
ROTATION soft key

Terminate the probe function by pressing the END
soft key

Saving a basic rotation in the preset table

After the probing process, enter the preset number in which the
TNC is to save the active basic rotation in the

Number in table:

input box

Press the BASIC ROT. IN PRESETTAB. soft key to save the basic
rotation in the preset table

Compensation of workpiece misalignment by rotating
the table

To compensate the identified misalignment by a rotary table
position, press the ALIGN ROTARY TABLE soft key after the
probing process

Position all axes to avoid a collision before table
rotation. The TNC outputs an additional warning
before table rotation.

If you want to set the datum in the rotary table axis, press the
SET TABLE ROTATION soft key.

You can also save the misalignment of the rotary table in any
line of the Preset table. Enter the line number and press the
TABLEROT IN PRESETTAB. soft key. The TNC saves the angle
in the offset column of the rotary table, e.g. in the C_OFFS
column with a C axis. If necessary, the view in the Preset table
has to be changed with the BASIS-TRANSFORM./OFFSET soft
key to display this column.