beautypg.com

HEIDENHAIN TNC 320 (34055x-06) User Manual

Page 418

background image

Manual operation and setup

12.8 Datum Setting with 3-D Touch Probe

12

418

TNC 320 | User's Manual HEIDENHAIN Conversational Programming | 5/2013

Outside circle:

Position the ball tip at a position near the first touch point
outside of the circle

Select the probe direction by soft key

To probe the workpiece, press the machine START button. If
you are not using the automatic probing routine, you need to
repeat this procedure. After the third probing operation, you
can have the TNC calculate the center (four touch points are
recommended).

Terminate the probing procedure and switch to the evaluation
menu: Press the EVALUATE soft key

Datum: Enter the coordinates of the datum and confirm your
entry with the SET DATUM soft key, or write the values to
a table (See "Writing measured values from the touch probe
cycles in a datum table", page 404
, or See "Writing measured
values from the touch probe cycles in the preset table",
page 405)

To terminate the probe function, press the END soft key

After the probing procedure is completed, the TNC displays the
current coordinates of the circle center and the circle radius PR.

Setting the datum using multiple holes/cylindrical studs

A second soft-key row provides a soft key for using multiple holes
or cylindrical studs to set the datum. You can set the intersection of
two or more elements as datum.

Select the probing function for the intersection of holes/cylindrical
studs:

Select the touch probe function: Press the
PROBING CC soft key

Hole is to be probed automatically: Define by soft
key

Circular stud is to be probed automatically: Define
by soft key

Preposition the touch probe approximately in the center of the hole
or near the first touch point of the circular stud. After you have
pressed the NC Start key, the TNC automatically probes the points
on the circle.

Move the touch probe to the next hole, repeat the probing
operation and have the TNC repeat the probing procedure until all
the holes have been probed to set the datum.