beautypg.com

2 wash nozzle removal – K-Patents PR-23 User Manual

Page 171

background image

11 Safe-Drive™

163

11.6.2 Wash nozzle removal

Warning! Always shut the main steam valve before performing any work on the
wash nozzle.

1

CLOSE

WARNING

Make absolutely certain that

the steam supply is shut off

before starting nozzle

removal procedure

1

3

2

1 Close the steam line supply valve (1).

2 Remove the steam supply line (2) and

the sensor flush flexible line (2) from the

nozzle T-piece.

Remove the nozzle guide locking screw

(3). Be careful, process pressure will try to

push the nozzle out from the process!

2

6

4

7

5

!

OPEN

CLOSE

4. Remove the safety pin (4).

5. Slide the nozzle out from the process

(5) until the guide plate stops it.

6. Close the nozzle isolation valve (6) by

turning the handle clockwise.

7. Open the 1/4’’ check port valve under

the nozzle isolation valve (7).

3

1

2

3

1. Lock the isolation valve handle with the

safety pin (1).

2. Remove the guide plate screw (2).

3. Remove the nozzle from the isolation

valve completely (3).