beautypg.com

7 pr-23-rp prism wash system, 9 sensor specifications 111 – K-Patents PR-23 User Manual

Page 119

background image

9 Sensor specifications

111

9.7.7 PR-23-RP prism wash system

A prism wash system is available for the PR-23-RP. This requires the use of a CFC-
RP-M20 flow-cell in combination with a 2” ANSI 300 CFC wash nozzle. Both of these
components are available from K-Patents. All the further components specifically re-
quired for the wash system installation, are obtained independently by the customer.
These include a 2” ANSI 300 to ½” ANSI 300 adapter, ½” ANSI check valve, ½” ANSI
300 shut-off valve, ½” supply piping for the wash media. See Figure 9.25

Figure 9.25

A prism wash system for PR-23-RP

Item.

Description

Supplied by

Pcs.

1

Indicating transmitter DTR

K-Patents

1

2

Sensor PR-23-RP

K-Patents

1

3

CFC-RP-M20 flow cell

K-Patents

1

4

2’’ ANSI 300 CFC wash nozzle

K-Patents

1

5

Cable between DTR and sensor

K-P/Customer

1

6

Main switch PR-10900

Customer/K-P

1

Item.

Description

Supplied by

Pcs.

7

Power supply 100-240 VAC/50-60Hz

Customer

1

8

Process pipe

Customer

1

9

2’’ ANSI 300 to 1/2”ANSI 300 adapter

Customer

1

10

Check valve ANSI 1/2”

Customer

1

11

1/2’’ ANSI 300 Valve

Customer

1

12

Wash supply 1/2”

Customer

1