9.10 PR-23 process refractometers in potentially

explosive atmosphere

The PR-23 refractometer series can be used in locations with potentially explosive
atmosphere with following modifications, made by K-Patents Oy. The refractometer
sensor’s compliance with the Essential Health and Safety Requirements is assured by
complying with standard EN 50 021:1999.

The PR-23-...-AX refractometers have been certified by DEKRA Certification B.V. un-
der the European ATEX directive 94/9/EC for ATEX Ex II 3G / EEx nA IIC T4 Gc
and under the IECEx scheme for Ex nA IIC T4 Gc. The Type-examination Certifi-
cate number is KEMA 05ATEX1183X and the IECEx Certificate number is IECEx KEM
10.0033X. These certifications cover the following Ex standards: EN 60079-0:2012 /
IEC 60079-0:2011, EN 60079-15:2010 / IEC 60079-15:2010.

The PR-23-...-FM refractometers are certified by Factory Mutual Research Corpora-
tion, Approval ID 3026104. Equipment Ratings: Nonincendive for use in Class I, Divi-
sion 2, Groups A, B, C & D, Hazardous (Classified) Locations. Temperature identifica-
tion rating for PR-23-...-FM is T6 (T

amb

= 45 °C).

The PR-23-...-CS refractometers are certified by Canadian Standards Association for
Class I, Division 2, Groups A-D. The Certificate Number is 1706327. Equipment Rat-
ings: Nonincendive for use in Class I, Division 2, Groups A, B, C & D, Hazardous (Clas-
sified) Locations. Temperature identification rating for PR-23-...-CS is T4 (T

amb

= 45

°C).

9.10.1 Equipment

The K-Patents refractometer system (Figure 9.31) for potentially explosive atmos-
phere locations consists of a modified refractometer sensor PR-23-...-AX/FM/CS, a
standard Indicating transmitter DTR and a sensor cable PR-8230-...

Hazardous area

(up to Zone 2)

Safe Area

PROCESS INSTRUMENTS

POWER

WIRING SEE WRG-342

Figure 9.31

Refractometer system PR-23-...-AX/FM/CS