K-Patents SeedMaster 2 User Manual
Seedmaster 2, Crystallization, Transmitter
INSTRUCTION MANUAL FOR THE
SeedMaster 2
Crystallization
Transmitter
and
Automatic
Seeding
Device
Document/Revision No. SeedMaster 2: Rev. 1/06
Effective: January 16, 2014.
PROCESS CONTROL KFT.
PROFICON Industrial Controls Ltd.
Postal address:
Postal address:
1091 BUDAPEST
1025 BUDAPEST
Haller u. 88.
Mandula u. 24.
HUNGARY
HUNGARY
E-mail: [email protected]
E-mail: [email protected]
www.processcontrol.hu
Table of contents
Document Outline
- 1 INTRODUCTION
- 2 SUGAR CRYSTALLIZATION IN BRIEF
- 2.1 The last step: crystallization
- 2.2 Supersaturation: the driving force of crystallization
- 2.3 Seeding methods
- 2.4 Crystal content
- 2.5 Product quality and supersaturation
- 2.6 Cost of production and the major parameters
- 2.7 Common instruments in use for crystallization control
- 2.8 Mounting the K-PATENTS refractometer
- 3 THE SEEDMASTER 2 CRYSTALLIZATION TRANSMITTER AND SEEDING DEVICE
- 3.1 SeedMaster 2 description
- 3.2 SeedMaster 2: a front-end device
- 3.3 Principle of operation
- 3.4 Calculated data
- 3.5 On-line data inputs
- 3.6 Digital inputs
- 3.6.1 “STRIKE ACTIVE” input DIN1
- 3.6.2 “SEEDED” input DIN2
- If instead of a single one, 2 or 3 (maximum) feed syrups having different syrup purities are to be fed to the same batch strike the device must be informed on the execution of the change. One way to do it is to use a digital input (DIN3).
- In this case information on purity and pan level may come in the form of 4-20 mA current from a PLC or DCS. If there are no level data available, the SeedMaster 2 will use typical simulated level data in the 35-80 % range. Operation of the DIN3 digita...
- 3.7 Data outputs
- 3.8 Digital (ON / OFF) outputs
- 3.9 The man-machine interface
- 4 TECHNICAL DATA, MOUNTING AND ELECTRICAL CONNECTIONS
- Device status
- 5 SEEDMASTER 2 FEATURES IN BRIEF
- 5.1 SeedMaster 2: OPERATOR STATION features
- 5.1.1 CONFIGURE
- 5.1.2 SET UP
- 5.1.3 DISPLAY
- 5.1.4 MANUAL OPERATIONS
- Manual seeding
- Change feed syrup purity
- If instead of a single one, 2 or 3 (maximum) feed syrups having different syrup purities are to be fed to the same batch strike the device must be informed on the execution of the change. This can be done by:
- Selecting MANUAL OPERATIONS from the MENU followed by CHANGE FSYRUP and CHANGE. The operation will step the feed syrup number to the next one (from 1 to 2, then to the maximum 3). (For more information on feed syrup changes see: 3.6.3).
- If a level transmitter is connected to the SeedMaster 2, using SETUP -> INPUTS -> FEED SYR. PUR up to 3 different purities and 2 level threshold data (where the change of purity should be made) can be selected from the keyboard to implement automatic ...
- If a level transmitter is connected to the SeedMaster 2 up to 3 different purities and 2 level thresholds can be sent via COMMUNICATION to implement automatic change of feed syrup purity.
- Finally, level, purity and level threshold data can all be sent via COMMUNICATION to implement automatic change of feed syrup purity.
- 5.2 SeedMaster 2: TRANSMITTER features
- 5.3 SeedMaster 2: SEEDING features
- 5.1 SeedMaster 2: OPERATOR STATION features
- 6 START UP AND USE
- 7 CONFIGURE SeedMaster 2
- 8 SET UP SeedMaster 2
- 9 MANUAL SEEDING
- 10 DISPLAY
- 11 COMMUNICATION
- 12 APPENDIX 1 : PROCEDURE TO EVALUATE THE “m”, “b” AND “c” COEFFICIENTS OF THE WIKLUND-VAVRINECZ SATURATION FUNCTION.
- APPENDIX 2 : CONFIGURATION DATA SHEETS