Acquisition Modules and Platinum Firmware
Monitoring Operations
less common unistation mode. Separate text fields are provided for specifying
selections for each.
Selector list for unistation: Accepts a space-separated list of channel
specifications. The channel name can be given in full or wild-cards and
negations can be used: A question-mark character (?) is a single wild-card and
will match any character in the same position; an exclamation-mark
character (!) can be used to deselect a channel, so
BHZ
selects just channel BHZ
BH?
selects channels BHZ, BHN and BHE
HH? !HHZ selects HHE and HHN but not HHZ
!HHE
selects all channels except HHE
Leaving this text field blank will select all channels.
Stream list for multistation: Can be left blank (to select all streams) or
populated with a comma-separated list of stream specifications. Each
specification is in the form NET_STA (where NET is the network identifier and
STA is the station identifier, as used in S.C.N.L notation), optionally followed
immediately by a colon (:) and then a space-separated list of channel
selectors, as described in the previous paragraph.
For example, say a system is processing the following channels (in S.C.N.L
notation):
B675.HHZ.KA.04
B675.CHZ.KA.0G
B675.SOH.KA.00
B675.HHE.KA.04
B675.HHN.KA.04
B675.BHE.KA.0M
B675.MME.KA.0A
B675.MMZ.KA.08
2200.BHN.GS.06
2200.HHE.GS.04
2200.HHN.GS.04
2200.BHE.GS.06
2200.BHZ.GS.06
2200.BHX.GS.06
2200.MMZ.GS.08
2200.MMN.GS.09
•
Leaving both the unistation and multistation lists blank will select all
data.
•
A specification of GS_2200 would select all data from station 2200.