Acquisition Modules and Platinum Firmware
Transmitting Data
Output type: The drop-down menu offers a choice of:
•
All blocks - filtering by block type is disabled
•
Only status blocks - no data blocks are transmitted
•
Only blocks below a certain sample rate - the threshold (inclusive) rate
is specified in the following text field.
•
Only blocks matching a list of channel names - offering the highest
granularity of control.
Max sample rate: If the output type is set to Only blocks below a certain
sample rate, the text field is used to specify the inclusive threshold, above
which data are not transmitted.
If the Output type field is set to Only blocks matching a list of channel
names, the channel names must be specified in the channel name table:
Channels should be specified by giving their system ID and their stream ID,
separated by a hyphen ('-').
Clicking the
button on any row will open a new row. In the same way,
rows can be deleted by clicking the corresponding
button.