Acquisition Modules and Platinum Firmware
Monitoring Operations
SAMPLES/SEC command (described in the DM24 manual). For
example, the command
dm24upgrade samp 1000 500 100 50 PortA
will set tap 0 to 1,000 samples per second and taps 1, 2 and 3 to 500,
100 and 50 samples per second respectively.
•
cont # # # #
This option specifies which streams will be enabled for continuous
output at each tap. This argument requires requires four numerical
values to be supplied using the same format as for the CONTINUOUS
command (described in the DM24 manual). For example, the
command
dm24upgrade cont 1 0 0 7
will turn on continuous output of the vertical component at tap 0
and of the three triaxial components at tap 3
•
trig # # # #
This option specifies which streams will be enabled for triggered
output at each tap. This argument requires requires four numerical
values to be supplied using the same format as for the TRIGGERED
command (described in the DM24 manual).
•
gpsbaud #
This option takes a single numerical argument which specifies the
Baud rate of the GPS port.
•
inbaud #
This option takes a single numerical argument which specifies the
Baud rate of the Data in port.
•
upgrade
Upgrade firmware files only (this is the default).
•
downgrade
This option over-rides internal version number checks, allowing
firmware to be downgraded as well as upgraded.
•
force
This option causes firmware files are to be loaded even if they appear
identical to the versions already loaded, or in cases where the
installed version number cannot be decoded.