beautypg.com

8 function select:utility:system – Comtech EF Data SDM-2020 User Manual

Page 84

background image

SDM-2020 Satellite Modulator

Revision 7

Front Panel Operation

MN/SDM2020M.IOM

5-42

5.6.8.8

FUNCTION SELECT:UTILITY:SYSTEM

TIME: 12:00:00AM

DATE: 7/04/76

The current time and date in the modulator memory are displayed. To set the modulator
time and/or date, proceed as follows:

1

Press

2

Press [

←] or [→] to position the flashing cursor over the parameter to be changed

3

Press [

↑] or [↓] to change the parameter to the desired value

4

Once the parameters are displayed as desired, press to set the time and date

REMOTE BAUD RATE

9600 BPS EVEN

The current baud rate and parity selection of the modulator are displayed. To set the
modulator baud rate and/or parity, proceed as follows:

1

Press .

2

Press [

←] or [→] to position the flashing cursor over the parameter to be changed.

3

Press [

↑] or [↓] to change the parameter to the desired value.

4

Once the parameters are displayed as desired, press to set the baud rate and
parity. The baud rate can be set from 300 to 19200. The parity can be set to EVEN, ODD, or
NONE.

REMOTE ADDRESS

1

The current modulator address is displayed (1 to 255). To set the remote address, proceed
as follows:

1

Press .

2

Press [

↑] or [↓] to change the parameter to the desired value.

3

Press to execute the change.

Note: Address 0 is reserved as a global address.