5.6.8.8
FUNCTION SELECT:UTILITY:SYSTEM
TIME: 12:00:00AM
DATE: 7/04/76
The current time and date in the modulator memory are displayed. To set the modulator
time and/or date, proceed as follows:
1
Press
2
Press [
←] or [→] to position the flashing cursor over the parameter to be changed
3
Press [
↑] or [↓] to change the parameter to the desired value
4
Once the parameters are displayed as desired, press
REMOTE BAUD RATE
9600 BPS EVEN
The current baud rate and parity selection of the modulator are displayed. To set the
modulator baud rate and/or parity, proceed as follows:
1
Press
2
Press [
←] or [→] to position the flashing cursor over the parameter to be changed.
3
Press [
↑] or [↓] to change the parameter to the desired value.
4
Once the parameters are displayed as desired, press
parity. The baud rate can be set from 300 to 19200. The parity can be set to EVEN, ODD, or
NONE.
REMOTE ADDRESS
1
The current modulator address is displayed (1 to 255). To set the remote address, proceed
as follows:
1
Press
2
Press [
↑] or [↓] to change the parameter to the desired value.
3
Press
Note: Address 0 is reserved as a global address.