7 configuration:modulator:carrier mode – Comtech EF Data SDM-2020 User Manual
Page 54

SDM-2020 Satellite Modulator
Revision 7
Front Panel Operation
MN/SDM2020M.IOM
5-12
5.6.1.7
CONFIGURATION:MODULATOR:CARRIER MODE
CARRIER MODE
NORMAL-MODULATED
Use this menu to program the modulator for continuous wave mode. Four modes of
operation are available:
NORMAL-
MODULATED
Normal modulated data. The Carrier Mode is in the OFF position for
data modulation.
DUAL-CW Mode
A test mode that generates a dual side-band suppressed carrier signal.
Side-bands are one-half the symbol rate from the carrier. This is used to
check the channel balance and carrier null.
OFFSET-CW
Mode
A test mode that generates a single upper side-band suppressed carrier
signal. The upper side-band is one-quarter the symbol rate from the
carrier. This is used to check the quadrature.
CENTER-CW
Mode
A test mode that generates a carrier at the current modulator frequency.
This can be used to measure the output frequency.
1
Press
2
Press