beautypg.com

Comtech EF Data SDM-2020 User Manual

Page 160

background image

SDM-2020 Satellite Modulator

Revision 7

ASI/LVDS Data Interfaces MN/SDM2020M.IOM

13-4

Table 13-1. ASI/LVDS Specifications (Continued)

Auxiliary Specifications

Fault Signal

MF (modulator fault) and DF (demodulator fault). OC-TTL fault outputs.

TX ON / OFF

TTL input, when enabled this signal turns the TX carrier ON / OFF.

Ext Clock

Pin(s) reserved, but not defined

Monitor & Control

Interface Select

ASI or LVDS

Auxiliary Functions Transmitter Control: TX IF Control ON / OFF

Polarity select Normal or Inverted

Controlled
Functions

Interface Select: ASI or LVDS

Interface Loopback

Interface Loop Thru

Data Rate

TX ASI Data Input J3 / J4 Select

Loss of data. Programmable as Fault or Alarm

Clock, Normal or Inverted

Data, Normal or Inverted

Monitored
Functions

Loss of TX Data (Data Connector Removed): The modulator indicates a loss of sync
(framed modes) and transmits all 1s in the data portion of the frame.

The demodulator detects the presence of all ones and reports it to the display and
remote port.

TX clock PLL program error

Data violations (TX)

FIFO Faults

ASI Data Loop BW
Selection

Wide and Narrow

Additional M&C

Monitored
Functions

Loss of TX Data or Clock (Data Connector Removed): The modulator indicates a
loss of sync (frame and mode) and transmits all 1s in the data portion of the frame.

The demodulator detects the presence of all ones and reports it to the display and
remote port.