beautypg.com

Auxiliary, j5, Lvds interface front panel menus, Lvds remote interface commands – Comtech EF Data SDM-2020 User Manual

Page 114: 6 lvds, 7 lvds

background image

SDM-2020 Satellite Modulator

Revision 7

Low Voltage Differential Signal (LVDS)

MN/SDM2020M.IOM

8-7

8.1.5

A

UXILIARY

, J5

This port provides for other modem-specific signals not otherwise defined on the
data connectors.

8.1.5.1

C

ONNECTOR

P

INOUT

J5

The connector is a sub-miniature, 9-pin D female, with threaded jack nuts. Differential
pairs are LVDS compatible.

Note: The sense of differential signal pairs is a logic “1” when “B” is positive with
respect to “A.”

Single-ended signals are open collector where:

Voh=12V max. and Vol=0.5V max. @ Iol=8 ma.

A pull-up resistor external to the equipment is required. The fault signals, MF and DF,
operate as follows: A fault is indicated by an “OFF” collector (high) and OK status is
indicated by an “ON” collector (low).

Table 8-3. Auxiliary Connector Pinout

Pin # Signal Function

Name

Type

Comment

1

GND

Signal

Ground

2

Demod Fault Indicator

DF

O

Demodulator Summary Fault
Redundancy switch application

3 Send

Timing

ST-A O

Modulator
SCT for terrestrial synchronization

4

N/C

5 Master

Clock

MC-B I

Demodulator

6

Mod Fault Indicator

MF

O

Modulator Summary Fault
Redundancy switch application

7 Carrier

Detect

/CD O

Demodulator

8 Send

Timing

ST-B O

Modulator
SCT for terrestrial synchronization

9 Master

Clock

MC-A I

Demodulator

8.1.6

LVDS

I

NTERFACE

F

RONT

P

ANEL

M

ENUS

Refer to Chapter 5, Utility Interface menu.

8.1.7

LVDS

R

EMOTE

I

NTERFACE

C

OMMANDS

Refer to Appendix A.