Smpte 310m commands, Ommands – Comtech EF Data SDM-2020 User Manual
Page 253

SDM-2020 Satellite Modulator
Revision 7
Remote Control Operation MN/SDM2020M.IOM
Para
Number
Parameter Name
(Command Reference)
Description
BCS
Parameters
23 to 32
23
24
25
26 thru 32
TX Interface Coding Format
(ref: 'ICFT_' commands).
Interface Loopback
(ref: 'ILB_' command).
Interface Loop Thru
(ref: 'ILM_' command).
Reserved.
p23 = n, where n is 0 (AMI), 1, (B3ZS), 2 (HDB3), or 3
(B8ZS).
p24 = n, where n = 0 (OFF) or 1 (ON).
p25 = n, where n = 0 (OFF) or 1 (ON).
A.11
SMPTE 310M C
OMMANDS
Parameter
Type
Command/
Status/
Response
Description of Arguments
Comments
Interface
Loop-back
Command:
Response:
Status:
Response:
Where: xxx = On or Off.
Interface Loop
Thru Mode
Command:
Response:
Status:
Response:
Where: xxx = On or Off.
RTS TX-IF
Control Mode
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.
This command configures the modem for the RTS
TX-IF control mode. If 'ON' is selected, the TX-IF
output will only be turned on if the incoming RTS
signal is asserted (also the TX-IF output has to be
programmed ON and no major modulator faults
are preset). If 'OFF' is selected, the TX-IF output
will operate normal ignoring the RTS signal.
RTS State
Control
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.
This command controls the logic of the RTS
signal.
Interface
Firmware
Information
Command:
Response:
FW/nnnnn-drr'cr'
mm/dd/yyyy'cr''lf'']
Where:
nnnnn = Firmware number (0 to 65535).
d = firmware dash number (0 to 99).
rr = Firmware revision (-, or A to ZZ).
A-36