beautypg.com

System configuration commands, A.2.6 s – Comtech EF Data SDM-2020 User Manual

Page 232

background image

SDM-2020 Satellite Modulator

Revision 7

Remote Control Operation MN/SDM2020M.IOM

Command/

Status/

Parameter Type

Response

Description of Arguments

Comments

TX Clock Activity
Action

Command:
Response:

Status:
Response:

>add/TCAA_xxxxx'cr''lf']

>add/TCAA_xxxxx'cr''lf']

Where: xxxxx = ALARM or FAULT.

A.2.6 S

YSTEM

C

ONFIGURATION

C

OMMANDS

Parameter

Type

Command/Status/

Response

Description of Arguments

Comments

Time Of Day Command:

Response:

Status:
Response:

>add/TIME_hh:mmxx'cr''lf']

>add/TIME_hh:mmxx'cr''lf']

Where:
hh = 1 to 12 (hours).
mm = 00 to 59 (minutes).
xx = AM or PM.

Date Command:

Response:

Status:
Response:

>add/DATE_mm/dd/yyyy'cr''lf']

>add/DATE_mm/dd/yyyy'cr''lf']

Where:
mm = 1 to 12 (month).
dd = 1 to 31 (day).
yy = 00 to 99 (year) in 2-digit year mode.
yyyy = 1975 to 1999, and 2000 to 2075 in 4-
digit mode.

Remote Command:

Response:

>add/REM_'cr''lf']

Configures the Modem for remote operation.

The modulator will respond to any status
request at any time. However, the modulator
must be in 'Remote Mode' to change
configuration parameters.

Clear Stored
Faults

Command:
Response:

>add/CLSF_'cr''lf']

This command is used to clear all stored faults
logged by the modulator.

Save Mod
Config.

Command:
Response:

>add/SMC_nn'cr''lf']

Where: n = 1, 2, 3, ..., 10 (stored configuration
number).

This command saves the current mod
configuration for recall at a later time using the
'RMC_' command. Up to ten different mod
configurations can be saved.

Recall Mod
Config.

Command:
Response:

>add/RMC_nn'cr''lf']

Where: n = 1, 2, 3, ..., 10 (stored configuration
number).

This command causes the mod to be
reprogrammed with configuration parameters
previously saved using the 'SMC_' command.
One of 10 saved configurations can be
specified.

A-15