Appendix C
MN-SLM5650A
C–36
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
AUPC Remote
Carrier Loss
Action
RCL=
1 byte, values
of 0 thru 2
Command or Query.
Tx Output Power level setting when remote carrier is lost, where:
0=Hold current output power level
1=Goto Nominal output power level
2=Goto Maximum output power level
Example: RCL=0
RCL=
RCL?
RCL*
RCL#
RCL?
RCL=x
(see Description
of Arguments)
Remote Modem
Pattern
Substitution
RPB=
1 byte, values
of 0 or 1
Command or Query.
Remote Modem Tx Pattern Substitution, where:
0=Off
1=On
Note: For compatibility reasons, only the 2047 Tx pattern can be turned On or Off at
the remote modem.
Example: RPB=1 (Turn on remote modem AUPC Control)
RPB=
RPB?
RPB*
RPB#
RPB?
RPB=x
(see Description
of Arguments)
Remote Modem
AUPC Enable
RPC=
1 byte, values
of 0 or 1
Command or Query.
Remote Modem AUPC Control, where:
0=Off
1=On
Example: RPC=1 (Turn on remote modem AUPC Control)
RPC=
RPC?
RPC*
RPC#
RPC?
RPC=x
(see Description
of Arguments)
Remote Modem
BERT BER
N/A
6 bytes
Query only.
Unit returns the value of the remote modem’s BERT BER in the form a.b x 10
-c
. First
three bytes are the value. Last two bytes are the exponent. Returns 0.0E00 if the
BERT is not synchronized to a pattern.
Example: RPE=4.0E06
N/A
RPE?
RPE=a.bEcc
(see Description
of Arguments)
Remote Modem
I/O Loopback
RPL=
1 byte, values
of 0 or 1
Command or Query.
Remote Modem I/O Loopback Mode, where:
0=Off
1=On
Example: RPL=1 (Turn on remote modem AUPC Control)
RPL=
RPL?
RPL*
RPL#
RPL?
RPL=x
(see Description