Monitor: alarms, Unit – Comtech EF Data SLM-5650A User Manual

Page 118

background image

SLM-5650A Satellite Modem

Revision 8

Front Panel Operation

MN-SLM5650A

5–36

Demod: ----

Demux not

Intf: +--------

locked

Monitor: Alarms

Unit

Unit: ---------------- Press for

------- detailed status

Press [ENT] to access the available read-only SLM-5650A Unit alarm screens. Then, use the


arrow keys to navigate through the displayed character positions (Unit#1 through #23). The

status message to the right changes based on the current cursor position, as per the following

table:

Unit Alarm Position

Description

Top row

Unit #1

Unit #2

Unit #3

Unit #4

Unit #5

Unit #6

Unit #7

Unit #8

Unit #9

Unit #10

Unit #11

Unit #12

Unit #13

Unit #14

Unit #15

Unit #16

+ 5 volt power supply is out of range.

+ 3.3 volt power supply is out of range.

+ 2.5 volt power supply is out of range.

+ 1.5 volt power supply is out of range.

+ 12 volt power supply is out of range.

- 12 volt power supply is out of range.

+ 18 volt power supply is out of range.

Cooling fan fault.

External reference activity status.

192 MHz clock Phase Lock Loop status.

10 MHz reference Phase Lock Loop status.

M&C FPGA configuration fault.

Modulator FPGA configuration fault.

Demodulator FPGA configuration fault.

Decoder FPGA configuration fault.

Transmit interface FPGA configuration fault.

Bottom row

Unit #17

Unit #18

Unit #19

Unit #20

Unit #21

Unit #22

Unit #23

Receive interface FPGA configuration fault.

FEC #1 FPGA configuration fault.

FEC #2 FPGA configuration fault.

Optional data interface card (module) FPGA configuration fault.

FPGA DCM Phase Lock Loop fault.

Network Processor mailbox communications error.

TRANSEC mailbox communications error.

The example that follows depicts the alarm status screen displayed if the Unit 1

st

character

position is selected:

Unit: +--------------- +5.0V Power is

----- out of range.