Monitor: alarms, Unit – Comtech EF Data SLM-5650A User Manual
Page 118

SLM-5650A Satellite Modem
Revision 8
Front Panel Operation
MN-SLM5650A
5–36
Demod: ----
Demux not
Intf: +--------
locked
Monitor: Alarms
Unit
Unit: ---------------- Press
------- detailed status
Press [ENT] to access the available read-only SLM-5650A Unit alarm screens. Then, use the
arrow keys to navigate through the displayed character positions (Unit#1 through #23). The
status message to the right changes based on the current cursor position, as per the following
table:
Unit Alarm Position
Description
Top row
Unit #1
Unit #2
Unit #3
Unit #4
Unit #5
Unit #6
Unit #7
Unit #8
Unit #9
Unit #10
Unit #11
Unit #12
Unit #13
Unit #14
Unit #15
Unit #16
+ 5 volt power supply is out of range.
+ 3.3 volt power supply is out of range.
+ 2.5 volt power supply is out of range.
+ 1.5 volt power supply is out of range.
+ 12 volt power supply is out of range.
- 12 volt power supply is out of range.
+ 18 volt power supply is out of range.
Cooling fan fault.
External reference activity status.
192 MHz clock Phase Lock Loop status.
10 MHz reference Phase Lock Loop status.
M&C FPGA configuration fault.
Modulator FPGA configuration fault.
Demodulator FPGA configuration fault.
Decoder FPGA configuration fault.
Transmit interface FPGA configuration fault.
Bottom row
Unit #17
Unit #18
Unit #19
Unit #20
Unit #21
Unit #22
Unit #23
Receive interface FPGA configuration fault.
FEC #1 FPGA configuration fault.
FEC #2 FPGA configuration fault.
Optional data interface card (module) FPGA configuration fault.
FPGA DCM Phase Lock Loop fault.
Network Processor mailbox communications error.
TRANSEC mailbox communications error.
The example that follows depicts the alarm status screen displayed if the Unit 1
st
character
position is selected:
Unit: +--------------- +5.0V Power is
----- out of range.