Comtech EF Data SLM-5650A User Manual
Page 369
SLM-5650A Satellite Modem
Revision 8
Appendix C
MN-SLM5650A
C–17
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Clock Invert RCI=
1 byte, value of 0
or 1
Command or Query.
Invert Receive Clock in the form x, where:
0=Normal
1=Inverted
Example: RCI=1 (selects Inverted RX Clock)
RCI =
RCI?
RCI*
RCI#
RCI?
RCI=x
(see Description
of Arguments)
Rx Clock
Source
RCK=
1 byte, value of 0
thru 3
Command or Query.
Rx Clock Source, where:
0=Rx Satellite
1=Internal
2=Tx-Terrestrial
3= External Clock (only valid with the G.703 Option Card)
Note: Commands as well as queries are not allowed when either the GigaBit
Ethernet or NP card has been selected as the current interface type.
Example: RCK=2 (selects Tx-Terrestrial)
RCK=
RCK?
RCK*
RCK#
RCK?
RCK=x
(see Description
of Arguments)
Rx
Reed-Solomon
Code Word
RCW=
1 byte, value of 0
to 5
Command or Query.
Rx RS encoding in the form x, where:
0 = RS(225,205,10)
1 = RS(219,201,9)
2 = RS(208,192,8)
3 = RS(194,178,8)
4 = RS(126,112,7)
5 = RS(220,200,10)
Depending on Modem mode, overhead type, and data rate, not all selections will be
valid.
Example: RCW=0 (This is a ‘don’t care’ if RS is Off under TRS)
RCW =
RCW?
RCW *
RCW #
RCW?
RCW=x
(see Description
of Arguments)
Rx Differential
Decoding
RDD=
1 byte, value of 0
or 1
Command or Query.
Rx Differential Decoding in the form x, where:
0=Off
1=On
Depending on FEC type or Modulation Type, not all selections will be valid.
Example: RDD=1 (selects Rx Differential Decoding On)
RDD=
RDD?
RDD*
RDD#
RDD?
RDD=x
(see Description
of Arguments)
Rx Data Fault
RDF=
1 byte, value of 0
thru 2
Command or Query.
Receive Data Fault, where:
0=None
1=DATA
2=AIS
Example: RDF=0 (selects Data Fault = None)
RDF =
RDF?
RDF*
RDF#
RDF?
RDF=x
(see Description
of Arguments)