beautypg.com

A.2.2 modulator checkout – Comtech EF Data SLM-5650A User Manual

Page 325

background image

SLM-5650A Satellite Modem

Revision 8

Appendix A

MN-SLM5650A

A–3

A.2.2 Modulator Checkout

Use the following procedure for modulator checkout:

Step

Task

1

Set up the equipment as shown in Figure A-1 using 70/140 MHz IF interface. Refer to Chapter 1.

INTRODUCTION for the modulator specifications.

2

Set up the modem for IF loopback operation by using TEST: Loopback IF from the front panel

menu, or use an external IF loop.

3

Clear all TX faults, Stored Faults, and Alarms using MONITOR: Event-Log Clear-All from the

front panel menu.

4

Measure the Eb/N0 with a receiver that is known to be properly operating:

a. Refer to Table A-1 and Figure A-2 to check for proper Eb/N0 level. The (S+N)/N is measured

by taking the average level of the noise and the average level of the modem spectrum top.

b. Use this measurement for the first column on Table A-1.
c. Read across the page to find the S/N and Eb/N0 for the specific code rate.

Once the demodulator has locked to the incoming signal, using MONITOR: Rx-Params

from the front panel menu displays frequency offset, signal level, BERT data (if enabled),

buffer status, Eb/N0, and corrected BER.

5

Connect a spectrum analyzer to the modem as shown in Figure A-1. Ensure the IF output meets

the appropriate mask and spurious specifications. Measure the power output at different levels and

frequencies.

A typical output spectrum is shown in Figure A-3.

6

Check the frequency and phase modulation accuracy as follows:

a. Set the modem to the continuous wave mode by using TEST: Carrier Tx-CW from the front

panel menu. This sets the Carrier modulation in the OFF condition. A pure carrier should now be

present at the IF output. This should only be used for frequency measurements. Spurious and

power measurements should be taken with the modulation on.

b. Set the modem to the continuous wave Offset mode by using TEST: Carrier Tx-1,0 from

the front panel menu. This generates a single upper side band and suppressed carrier signal.

Ensure the carrier and side-band suppression are < -30 dBc.

7

Repeat steps 2-6 using the L-Band IF interface.