Comtech EF Data SLM-5650A User Manual

Page 378

background image

SLM-5650A Satellite Modem

Revision 8

Appendix C

MN-SLM5650A

C–26

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Live Unit Faults N/A

8 bytes

Query only.
Live Unit Faults are returned as a 32 bit Hexadecimal value. Bit values are defined

as follows:

80000000 = +5.0V Power

40000000 = +3.3V Power

20000000 = +2.5V Power

10000000 = +1.5V Power

08000000 = +12V Power

04000000 = -12V Power

02000000 = +18V Power

01000000 = Cooling Fan

00800000 = Ext Reference Activity

00400000 = 192 MHz Clock not locked

00200000 = 10 MHz Ref Clock not locked

00100000 = M&C FPGA not loaded

00080000 = Mod FPGA not loaded

00040000 = Demod FPGA not loaded

00020000 = Decoder FPGA not loaded

00010000 = Tx Interface FPGA not loaded

00008000 = Rx Interface FPGA not loaded

00004000 = FEC #1 FPGA not loaded

00002000 = FEC #2 FPGA not loaded

00001000 = Option Card FPGA not loaded

00000800 = FPGA DCM not locked

00000400 = NP Card Mailbox Comm Error

00000200 = FIPS Card Mailbox Comm Error

Example: LUF=00000000 indicates No Unit Faults

N/A

LUF?

LUF=xxxxxxxx

(see Description

of Arguments)

Number of

Unread stored

Events

N/A

3 bytes

Query only.
Unit returns the Number of stored Events, which remain Unread, in the form xxx.
Note: This means unread over the remote control.
Example: NUE=126

N/A

NUE?

NUE=xxx

(see Description

of Arguments)

Number of

Unread stored

Statistics

N/A

3 bytes

Query only.
Unit returns the Number of stored Statistics, which remain Unread, in the form xxx.
Note: This means unread over the remote control.
Example: NUS=126

N/A

NUS?

NUS=xxx

(see Description

of Arguments)